About Megacon
Worldwide contacts
Contact us
Megacon Home
Renewable Energy Solutions
Insulation Monitoring
AC Guards
KPM161x
KCM161x
KPM163x
KCM163x
KPM165x
KCM165x
KPM161Mx
KCM161Mx
KPM163Mx
KPM161FQx
KCM161FQx
KPM163FQx
KCM163FQx
KPM26x
KCM26x
AC Transducers
AC Trip Relays
AC High Voltage Adaptors
AC Loop Sensor Modules
DC Guards
DC Trip Relays Live
DC Trip Relay Non-Live
DC High Voltage Adaptors
Insulation Test Unit
Earth Fault Monitoring
Earth Fault Protection
Battery Voltage Guard
Controllers and Guards
Current Guards AC or DC
Generator Protection
Generator Controls
Synchronisers
Freq. & Voltage Guards
Phase Sequence Control
Loss of Mains Protection
Measuring Transducers
Temperature Guards
Current Transformers
Panel Instruments
Switches
Shunts
Power & Test Equipment
Dewpoint & Hygrometers
Insulation Guards AC
KPM161x
INSULATION GUARD FOR NON-GROUNDED AC NETWORKS
Direct connection up to 690V line voltage, up to 1,4kV with HV adapter for both single or three phase systems
(Panel mounting)
KCM161x
INSULATION GUARD FOR NON-GROUNDED AC NETWORKS
Direct connection up to 690V line voltage for both single or three phase systems
(DIN Rail mounting)
KPM163x
INSULATION GUARD FOR NON-GROUNDED AC NETWORKS
Direct connection up to 690V line voltage, up to 6,6kV with HV adapter for both single or three phase systems
(Panel mounting)
KCM163x
INSULATION GUARD FOR NON-GROUNDED AC NETWORKS
Direct connection up to 690V line voltage, up to 6,6kV with HV adapter for both single or three phase systems
(DIN Rail mounting)
KPM165x
INSULATION GUARD FOR NON-GROUNDED AC NETWORKS
Direct connection up to 500V line voltage, up to 25kV with HV adapter for both single or three phase systems
(Panel mounting)
KCM165x
INSULATION GUARD FOR NON-GROUNDED AC NETWORKS
Direct connection up to 690V line voltage, up to 25kV with HV adapter for both single or three phase systems
(DIN Rail mounting)
KPM161Mx
AC INSULATION GUARD WITH HIGH ENERGY DC PROTECTION
Direct connection up to 690V line voltage, up to 1,4kV with HV adapter for both single or three phase systems
(Panel mounting)
KCM161Mx
AC INSULATION GUARD WITH HIGH ENERGY DC PROTECTION
Direct connection up to 690V line voltage, up to 1,4kV with HV adapter for both single or three phase systems
(DIN Rail mounting)
KPM163Mx
AC INSULATION GUARD WITH HIGH ENERGY DC PROTECTION
Direct connection up to 690V line voltage, up to 6,6kV with HV adapter for both single or three phase systems
(Panel mounting)
KPM161FQx
INSULATION GUARD FOR IT-NETWORKS WITH FREQUENCY CONVERTERS
Direct connection up to 690V line voltage, up to 1,4kV with HV adapter for both single or three phase systems
(Panel mounting)
KCM161FQx
INSULATION GUARD FOR IT-NETWORKS WITH FREQUENCY CONVERTERS
Direct connection up to 690V line voltage, up to 1,4kV with HV adapter for both single or three phase systems
(DIN Rail mounting)
KPM163FQx
INSULATION GUARD FOR IT-NETWORKS WITH FREQUENCY CONVERTERS
Direct connection up to 690V line voltage, up to 6,6kV with HV adapter for both single or three phase systems
(Panel mounting)
KCM163FQx
INSULATION GUARD FOR IT-NETWORKS WITH FREQUENCY CONVERTERS
Direct connection up to 690V line voltage, up to 6,6kV with HV Adapter for both single or three phase systems
(DIN Rail mounting)
KPM26x
AC INSULATION GUARD WITH MEASURING LOOP SUPERVISION
Direct connection up to 690V line voltage, up to 6,6kV with HV adapter for both single or three phase systems
(Panel mounting)
KCM26x
AC INSULATION GUARD WITH MEASURING LOOP SUPERVISION
Direct connection up to 690V line
voltage, up to 6,6kV with HV adapter for both single or three phase systems
(DIN Rail mounting)
{1}
##LOC[OK]##
{1}
##LOC[OK]##
##LOC[Cancel]##
{1}
##LOC[OK]##
##LOC[Cancel]##
Megacon Norway United Kingdom Denmark
Web solution by Digitroll